skip to primary navigation skip to content
 

 

You are not currently logged in

SPRI library catalogue

View a record

Please note: You are viewing the legacy database of the Scott Polar Research Institute Library catalogue. It is no longer being updated, so does not reliably reflect our current library holdings.

Please search for material in iDiscover for up-to-date information about the library collection.


Record #78839:

Numerical two-dimensional study of thermal behaviour around a cylindrical cooled underground cavity. Domain of validity of an axisymmetrical scheme / A.M. Cames-Pintaux, M. Nguyen-Lamba, J. Aguirre-Puente.

Title: Numerical two-dimensional study of thermal behaviour around a cylindrical cooled underground cavity. Domain of validity of an axisymmetrical scheme / A.M. Cames-Pintaux, M. Nguyen-Lamba, J. Aguirre-Puente.
Author(s): Cames-Pintaux, A. M.
Nguyen-Lamba, M.
Aguirre-Puente, J.
Date: 1986.
In: Cold Regions Science and Technology. (1986.), Vol. 12(2) (1986)
Abstract: Numerical model involving finite element based on enthalpy is proposed for solution of two-dimensional problems of heat transfer with phase change. Used to study thermal behaviour of soil around tank used for cryogenic storage, which is buried at depth of 23 m, in Belgium.
Notes:

Cold Regions Science and Technology. Vol. 12(2) :105-114 (1986).

Keywords: 624.139.262 -- Bearing capacity of ground, effect of freezing.
519.673 -- Modelling.
E12 -- Glaciology: frozen ground / snow and ice engineering.
SPRI record no.: 78839

MARCXML

LDR 01232naa#a2200000#a#4500
001 SPRI-78839
005 20240319054626.0
007 ta
008 240319s1986####xx#a##|##|###|0||#0|eng#d
035 ## ‡aSPRI-78839
040 ## ‡aUkCU-P‡beng‡eaacr
100 1# ‡aCames-Pintaux, A. M.
245 10 ‡aNumerical two-dimensional study of thermal behaviour around a cylindrical cooled underground cavity. Domain of validity of an axisymmetrical scheme /‡cA.M. Cames-Pintaux, M. Nguyen-Lamba, J. Aguirre-Puente.
260 ## ‡a[S.l.] :‡b[s.n.],‡c1986.
300 ## ‡ap. 105-114 :‡bdiags.
500 ## ‡aCold Regions Science and Technology. Vol. 12(2) :105-114 (1986).
520 3# ‡aNumerical model involving finite element based on enthalpy is proposed for solution of two-dimensional problems of heat transfer with phase change. Used to study thermal behaviour of soil around tank used for cryogenic storage, which is buried at depth of 23 m, in Belgium.
650 07 ‡a624.139.262 -- Bearing capacity of ground, effect of freezing.‡2udc
650 07 ‡a519.673 -- Modelling.‡2udc
650 07 ‡aE12 -- Glaciology: frozen ground / snow and ice engineering.‡2local
700 1# ‡aNguyen-Lamba, M.
700 1# ‡aAguirre-Puente, J.
773 0# ‡7nnas ‡tCold Regions Science and Technology. ‡gVol. 12(2) (1986) ‡wSPRI-59075
917 ## ‡aUnenhanced record from Muscat, imported 2019
948 3# ‡a20240319