skip to primary navigation skip to content
 

 

You are not currently logged in

SPRI library catalogue

View a record

Please note: You are viewing the legacy database of the Scott Polar Research Institute Library catalogue. It is no longer being updated, so does not reliably reflect our current library holdings.

Please search for material in iDiscover for up-to-date information about the library collection.


Record #126924:

The influence of filling charge, evaporator length and condenser length on the performance of a right-angled thermosyphon / G.S.H. Lock, Jialin Fu.

Title: The influence of filling charge, evaporator length and condenser length on the performance of a right-angled thermosyphon / G.S.H. Lock, Jialin Fu.
Author(s): Lock, G. S. H.
Fu, Jialin.
Date: 1993.
Publisher: New York: American Society of Mechanical Engineers
In: OMAE 1993. Proceedings of the 12th International Conference on Offshore Mechanics and Arctic Engineering. Volume IV. Arctic/Polar technology. (1993.),
Abstract: Reports experimental investigation of evaporative thermosyphon with right-angled configuration in which horizontal condenser lies above vertical evaporator; this configuration is suitable for many de-icing purposes. Particular attention given to filling quantity, measured as fraction of evaporator volume, and effects of condenser and evaporator length. Several behavioural regimes were identified and used to explain variations in heat-transfer rate.
Notes:

In: OMAE 1993. Proceedings of the 12th International Conference on Offshore Mechanics and Arctic Engineering. Volume IV. Arctic/Polar technology / Wilfrid A. Nixon, Devinder S. Sodhi, Nirmal K. Sinha, Olufemi A. Ayorinde, eds.

Keywords: 621.5 -- Refrigeration and heat pumps.
621.577 -- Heat pumps.
624.14 -- Snow and ice engineering.
624.143.54 -- De-icing methods, thermal.
M -- Engineering and construction.
SPRI record no.: 126924

MARCXML

LDR 01807naa#a2200000#a#4500
001 SPRI-126924
005 20240418095958.0
007 ta
008 240418s1993####nyua###|#####|0||#0#eng#d
035 ## ‡aSPRI-126924
040 ## ‡aUkCU-P‡beng‡eaacr
100 1# ‡aLock, G. S. H.
245 14 ‡aThe influence of filling charge, evaporator length and condenser length on the performance of a right-angled thermosyphon /‡cG.S.H. Lock, Jialin Fu.
260 ## ‡aNew York :‡bAmerican Society of Mechanical Engineers,‡c1993.
300 ## ‡ap. 207-211 :‡bdiags., table.
500 ## ‡aIn: OMAE 1993. Proceedings of the 12th International Conference on Offshore Mechanics and Arctic Engineering. Volume IV. Arctic/Polar technology / Wilfrid A. Nixon, Devinder S. Sodhi, Nirmal K. Sinha, Olufemi A. Ayorinde, eds.
520 3# ‡aReports experimental investigation of evaporative thermosyphon with right-angled configuration in which horizontal condenser lies above vertical evaporator; this configuration is suitable for many de-icing purposes. Particular attention given to filling quantity, measured as fraction of evaporator volume, and effects of condenser and evaporator length. Several behavioural regimes were identified and used to explain variations in heat-transfer rate.
650 07 ‡a621.5 -- Refrigeration and heat pumps.‡2udc
650 07 ‡a621.577 -- Heat pumps.‡2udc
650 07 ‡a624.14 -- Snow and ice engineering.‡2udc
650 07 ‡a624.143.54 -- De-icing methods, thermal.‡2udc
650 07 ‡aM -- Engineering and construction.‡2local
700 1# ‡aFu, Jialin.
773 0# ‡7nnam ‡aWilfrid A. Nixon, Devinder S. Sodhi, Nirmal K. Sinha, Olufemi A. Ayorinde, eds. ‡tOMAE 1993. Proceedings of the 12th International Conference on Offshore Mechanics and Arctic Engineering. Volume IV. Arctic/Polar technology. ‡dNew York : American Society of Mechanical Engineers, 1993. ‡wSPRI-126899
917 ## ‡aUnenhanced record from Muscat, imported 2019
948 3# ‡a20240418