Record #106925:

Laboratory investigation of trash rack heating to prevent freezeup by frazil ice / Steven F. Daly, Frank Donald Haynes, Donald E. Garfield, John J. Gagnon.

Title: Laboratory investigation of trash rack heating to prevent freezeup by frazil ice / Steven F. Daly, Frank Donald Haynes, Donald E. Garfield, John J. Gagnon.
Author(s): Daly, Steven F.
Haynes, Frank Donald.
Garfield, Donald E.
Gagnon, John J.
Date: 1990.
Publisher: Espoo: Helsinki University of Technology
In: IAHR. The 10th Symposium on Ice, August 20-24, 1990, Espoo, Finland. Proceedings. (1990.), Vol. 2.
Abstract: If practical problems can be overcome, heating upstream face of trash rack bars can be effective and relatively economical anti-icing method, e.g. with bar spacing of 10 cm and minimum heating rate of 40 W m⁻¹, total energy requirement would be 0.4 kW m⁻². Discussion, Vol. 3, p. 381-383.
Notes:

In: IAHR. The 10th Symposium on Ice, August 20-24, 1990, Espoo, Finland. Proceedings. Vol. 2. / International Association for Hydrological Research.

Keywords: 624.146 -- Anchor ice and frazil ice, damage.
624.14 -- Snow and ice engineering.
E12 -- Glaciology: frozen ground / snow and ice engineering.
SPRI record no.: 106925

MARCXML

LDR 01474naa#a2200000#a#4500
001 SPRI-106925
005 20240328185642.0
007 ta
008 240328s1990####fi#a###|#####|0||#0#eng#d
035 ## ‡aSPRI-106925
040 ## ‡aUkCU-P‡beng‡eaacr
245 00 ‡aLaboratory investigation of trash rack heating to prevent freezeup by frazil ice /‡cSteven F. Daly, Frank Donald Haynes, Donald E. Garfield, John J. Gagnon.
260 ## ‡aEspoo :‡bHelsinki University of Technology,‡c1990.
300 ## ‡ap. 584-595 :‡bdiags.
500 ## ‡aIn: IAHR. The 10th Symposium on Ice, August 20-24, 1990, Espoo, Finland. Proceedings. Vol. 2. / International Association for Hydrological Research.
520 3# ‡aIf practical problems can be overcome, heating upstream face of trash rack bars can be effective and relatively economical anti-icing method, e.g. with bar spacing of 10 cm and minimum heating rate of 40 W m⁻¹, total energy requirement would be 0.4 kW m⁻². Discussion, Vol. 3, p. 381-383.
650 07 ‡a624.146 -- Anchor ice and frazil ice, damage.‡2udc
650 07 ‡a624.14 -- Snow and ice engineering.‡2udc
650 07 ‡aE12 -- Glaciology: frozen ground / snow and ice engineering.‡2local
700 1# ‡aDaly, Steven F.
700 1# ‡aHaynes, Frank Donald.
700 1# ‡aGarfield, Donald E.
700 1# ‡aGagnon, John J.
773 0# ‡7c2am ‡aInternational Association for Hydrological Research. ‡tIAHR. The 10th Symposium on Ice, August 20-24, 1990, Espoo, Finland. Proceedings. ‡dEspoo : Helsinki University of Technology, 1990. ‡gVol. 2. ‡wSPRI-106673
917 ## ‡aUnenhanced record from Muscat, imported 2019
948 3# ‡a20240328