Ice lens orientation around a chilled buried pipe / Sharon L. Smith, Peter J. Williams.

Title: Ice lens orientation around a chilled buried pipe / Sharon L. Smith, Peter J. Williams.
Author(s): Smith, Sharon L.
Williams, Peter J.
Date: 1990.
In: Collection Nordicana. (1990.), Vol. 54 (1990)
Abstract: Observed in temperature-controlled facility. Comparison of ice-lens pattern to isotherm pattern in section perpendicular to pipe axis indicated that, while chilled pipe influences orientation near pipe, it is not the only factor controlling pattern; variations in soil density and mechanical properties of frozen soil also influence this. Appears that heave consists of vertical and lateral components, and displacement of pipe is result of pipe being squeezed as well as being lifted by vertical heave generated directly below it.
Notes:

Collection Nordicana. Vol. 54 :83-87 (1990).

Keywords: 624.139.22 -- Frost heave.
622.323 -- Petroleum, exploitation of resources.
551.345.3 -- Permafrost, composition and structure. Ice wedges.
551.345 -- Permafrost. Cryopedology.
E12 -- Glaciology: frozen ground / snow and ice engineering.
SPRI record no.: 105009

MARCXML

LDR 01430naa#a2200000#a#4500
001 SPRI-105009
005 20240416180552.0
007 ta
008 240416s1990####xx#a##|##|###|0||#0|eng#d
035 ## ‡aSPRI-105009
040 ## ‡aUkCU-P‡beng‡eaacr
100 1# ‡aSmith, Sharon L.
245 10 ‡aIce lens orientation around a chilled buried pipe /‡cSharon L. Smith, Peter J. Williams.
260 ## ‡a[S.l.] :‡b[s.n.],‡c1990.
300 ## ‡ap. 83-87 :‡bill., diags.
500 ## ‡aCollection Nordicana. Vol. 54 :83-87 (1990).
520 3# ‡aObserved in temperature-controlled facility. Comparison of ice-lens pattern to isotherm pattern in section perpendicular to pipe axis indicated that, while chilled pipe influences orientation near pipe, it is not the only factor controlling pattern; variations in soil density and mechanical properties of frozen soil also influence this. Appears that heave consists of vertical and lateral components, and displacement of pipe is result of pipe being squeezed as well as being lifted by vertical heave generated directly below it.
650 07 ‡a624.139.22 -- Frost heave.‡2udc
650 07 ‡a622.323 -- Petroleum, exploitation of resources.‡2udc
650 07 ‡a551.345.3 -- Permafrost, composition and structure. Ice wedges.‡2udc
650 07 ‡a551.345 -- Permafrost. Cryopedology.‡2udc
650 07 ‡aE12 -- Glaciology: frozen ground / snow and ice engineering.‡2local
700 1# ‡aWilliams, Peter J.
773 0# ‡7nnas ‡tCollection Nordicana. ‡gVol. 54 (1990) ‡wSPRI-47956
917 ## ‡aUnenhanced record from Muscat, imported 2019
948 3# ‡a20240416